Application
The Conduspar Line of Parallel 300 V is suitable for temporary connections, such as extension cords, lamp power andsimilar equipment.
Construction
Conductor: bare electrolytic copper wire, soft hardness, class 1, acc. to NM 280.
Insulation: thermoplastic compound of PVC/D.
Available colors: white and brown.
Maximum Operating Temperature
Continuous regime: 70°C
Reference Standards
ABNT NBR NM 247-5 – Insulated cables with polyvinyl chloride for nominal voltages up to 450/750 V, including – Part 5: Flexibles cables (cords) (IEC 60227-5, MOD).
ABNT NBR NM 280 – Conductors of insulated cables (IEC 60228, MOD).
Conditioning
In rolls of 100 m or in reels.
Nominal Dimensions